Every water filter certified to reduce PFAS
Key facts
- 492 models are certified by IAPMO R&T, 80 by WQA and 66 by NSF (registries checked November 17, 2026).
- 302 models carry the "Total PFAS" claim; the others are certified for PFOA and PFOS reduction.
- Brands with the most certified models: PUR (53), eSpring (Amway) (34), PureBlueH2O (34), Coway (32), Culligan Korea (29), Amazon Basics (24), Caware (24), AquaTru (23).
- A certification covers the exact model and its replacement cartridge. A different model of the same brand can have no PFAS claim at all.
How to read this list
Each row is one model as the registry lists it, with the standard, the PFAS claim and a link to the listing. PFAS claims sit under NSF/ANSI 53 (most filters, and often the carbon stage of a reverse osmosis system) or NSF/ANSI 58 (the reverse osmosis claim itself). We show only these two current standards; older P473 listings and duplicate CSA entries are left out.
Not sure what is in your water? Check your ZIP code first, then read how to pick a PFAS filter.
All certified models
638 models from 100 brands
A. O. Smith9 models
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| AO-FFReplacement: AO-US-100-R | Not stated | NSF/ANSI 53 | PFOA, PFOS | 200 gal | WQA |
| AO-US-200Replacement: AO-US-200-R | Not stated | NSF/ANSI 53 | PFOA, PFOS | 500 gal | WQA |
| AO-US-200 1Replacement: AO-US-200-R | Under-sink | NSF/ANSI 53 | PFOA, PFOS | 500 gal | WQA |
| AO-US-RO-MB-40001Replacement: AO-US-RO-MB-R, AO-US-RO-MEM | Reverse osmosis | NSF/ANSI 53 | PFOA, PFOS | 365 gal | IAPMO |
| AOS-CH-1000-PBReplacement: CT-05-CB-AMCYL-IO | Whole house | NSF/ANSI 53 | PFOA, PFOS | 75,327 gal | IAPMO |
| AOS-HS-1200 2 3Replacement: AOS-HS-1200-R | Whole house | NSF/ANSI 53 | PFOA, PFOS, PFNA, PFHpA, PFHxS | 500,000 gal | WQA |
| AOW-2000Replacement: AOW-2000-R | Not stated | NSF/ANSI 53 | PFOA, PFOS | 500 gal | WQA |
| AOW-3000Replacement: AOW-3000-R | Not stated | NSF/ANSI 53 | PFOA, PFOS | 365 gal | WQA |
| High Efficiency Reverse Osmosis AOS-HERO-CHRReplacement: AOS-HERO-S1S3 | Reverse osmosis | NSF/ANSI 53 | PFOA, PFOS | 250 gal | WQA |
Acorn5 models
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| 7004-302-002Replacement: 7012-347-000 | Not stated | NSF/ANSI 53 | Total PFAS | 3,000 gal | IAPMO |
| 7012-347-001Replacement: 7012-347-000 | Not stated | NSF/ANSI 53 | Total PFAS | 3,000 gal | IAPMO |
| 7012-347-002Replacement: RWF3000 | Not stated | NSF/ANSI 53 | Total PFAS | 3,000 gal | IAPMO |
| WF3001Replacement: 7012-347-000 | Not stated | NSF/ANSI 53 | Total PFAS | 3,000 gal | IAPMO |
| WF3EZReplacement: 7012-347-000 | Not stated | NSF/ANSI 53 | Total PFAS | 3,000 gal | IAPMO |
AlwaysFresh2 models
Amazon Basics24 models
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| EFF-6002S2Also sold as AQUA CREST, AquaCrest, Aquasu, BBY Essential, Ecoaqua, Filterlogic, Fridgetastic, HDX, INSIGNIA, Kohler, Maxblue, OverbestReplacement: EFF-6002A2 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 300 gal | IAPMO |
| EFF-6005S2Also sold as AQUA CREST, AquaCrest, Aquasu, BBY Essential, Ecoaqua, Filterlogic, Fridgetastic, HDX, INSIGNIA, Kohler, Maxblue, OverbestReplacement: EFF-6005A2 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 300 gal | IAPMO |
| EFF-6007S2Also sold as AQUA CREST, AquaCrest, Aquasu, BBY Essential, Ecoaqua, Filterlogic, Fridgetastic, HDX, INSIGNIA, Kohler, Maxblue, OverbestReplacement: EFF-6007A2 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 300 gal | IAPMO |
| EFF-6008S2Also sold as AQUA CREST, AquaCrest, Aquasu, BBY Essential, Ecoaqua, Filterlogic, Fridgetastic, HDX, INSIGNIA, Kohler, Maxblue, OverbestReplacement: EFF-6008A2 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 300 gal | IAPMO |
| EFF-6011S2Also sold as AQUA CREST, AquaCrest, Aquasu, BBY Essential, Ecoaqua, Filterlogic, Fridgetastic, HDX, INSIGNIA, Kohler, Maxblue, OverbestReplacement: EFF-6011A2 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 300 gal | IAPMO |
| EFF-6013S2Also sold as AQUA CREST, AquaCrest, Aquasu, BBY Essential, Ecoaqua, Filterlogic, Fridgetastic, HDX, INSIGNIA, Kohler, Maxblue, OverbestReplacement: EFF-6013A2 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 300 gal | IAPMO |
| EFF-6020S2Also sold as AQUA CREST, AquaCrest, Aquasu, BBY Essential, Ecoaqua, Filterlogic, Fridgetastic, HDX, INSIGNIA, Kohler, Maxblue, OverbestReplacement: EFF-6020A2 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 200 gal | IAPMO |
| EFF-6027S2Also sold as AQUA CREST, AquaCrest, Aquasu, BBY Essential, Ecoaqua, Filterlogic, Fridgetastic, HDX, INSIGNIA, Kohler, Maxblue, OverbestReplacement: EFF-6027A2 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 300 gal | IAPMO |
| EFF-6032S2Also sold as AQUA CREST, AquaCrest, Aquasu, BBY Essential, Ecoaqua, Filterlogic, Fridgetastic, HDX, INSIGNIA, Kohler, Maxblue, OverbestReplacement: EFF-6032A2 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 200 gal | IAPMO |
| EFF-6038S2Also sold as AQUA CREST, AquaCrest, Aquasu, BBY Essential, Ecoaqua, Filterlogic, Fridgetastic, HDX, INSIGNIA, Kohler, Maxblue, OverbestReplacement: EFF-6038A2 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 200 gal | IAPMO |
| EFF-6045S2Also sold as AQUA CREST, AquaCrest, Aquasu, BBY Essential, Ecoaqua, Filterlogic, Fridgetastic, HDX, INSIGNIA, Kohler, Maxblue, OverbestReplacement: EFF-6045A2 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 270 gal | IAPMO |
| EFF-6046S2Also sold as AQUA CREST, AquaCrest, Aquasu, BBY Essential, Ecoaqua, Filterlogic, Fridgetastic, HDX, INSIGNIA, Kohler, Maxblue, OverbestReplacement: EFF-6046A2 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 200 gal | IAPMO |
| EQW-1Also sold as AQUA CREST, AquaCrest, Aquasu, BBY Essential, Ecoaqua, Filterlogic, Fridgetastic, HDX, INSIGNIA, Kohler, Maxblue, OverbestReplacement: EQW-1 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 200 gal | IAPMO |
| EQW-3Also sold as AQUA CREST, AquaCrest, Aquasu, BBY Essential, Ecoaqua, Filterlogic, Fridgetastic, HDX, INSIGNIA, Kohler, Maxblue, OverbestReplacement: EQW-3 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 300 gal | IAPMO |
| FMG-1Also sold as AQUA CREST, AquaCrest, Aquasu, BBY Essential, Ecoaqua, Filterlogic, Fridgetastic, HDX, INSIGNIA, Kohler, Maxblue, OverbestReplacement: FMG-1 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 300 gal | IAPMO |
| FML-1Also sold as AQUA CREST, AquaCrest, Aquasu, BBY Essential, Ecoaqua, Filterlogic, Fridgetastic, HDX, INSIGNIA, Kohler, Maxblue, OverbestReplacement: FML-1 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 300 gal | IAPMO |
| FML-3Also sold as AQUA CREST, AquaCrest, Aquasu, BBY Essential, Ecoaqua, Filterlogic, Fridgetastic, HDX, INSIGNIA, Kohler, Maxblue, OverbestReplacement: FML-3 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 200 gal | IAPMO |
| FML-4Also sold as AQUA CREST, AquaCrest, Aquasu, BBY Essential, Ecoaqua, Filterlogic, Fridgetastic, HDX, INSIGNIA, Kohler, Maxblue, OverbestReplacement: FML-4 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 200 gal | IAPMO |
| FML-5Also sold as AQUA CREST, AquaCrest, Aquasu, BBY Essential, Ecoaqua, Filterlogic, Fridgetastic, HDX, INSIGNIA, Kohler, Maxblue, OverbestReplacement: FML-5 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 200 gal | IAPMO |
| FMM-2Also sold as AQUA CREST, AquaCrest, Aquasu, BBY Essential, Ecoaqua, Filterlogic, Fridgetastic, HDX, INSIGNIA, Kohler, Maxblue, OverbestReplacement: FMM-2 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 300 gal | IAPMO |
| FMS-1Also sold as AQUA CREST, AquaCrest, Aquasu, BBY Essential, Ecoaqua, Filterlogic, Fridgetastic, HDX, INSIGNIA, Kohler, Maxblue, OverbestReplacement: FMS-1 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 300 gal | IAPMO |
| FMS-2Also sold as AQUA CREST, AquaCrest, Aquasu, BBY Essential, Ecoaqua, Filterlogic, Fridgetastic, HDX, INSIGNIA, Kohler, Maxblue, OverbestReplacement: FMS-2 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 300 gal | IAPMO |
| FMS-4Also sold as AQUA CREST, AquaCrest, Aquasu, BBY Essential, Ecoaqua, Filterlogic, Fridgetastic, HDX, INSIGNIA, Kohler, Maxblue, OverbestReplacement: FMS-4 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 270 gal | IAPMO |
| FMW-2Also sold as AQUA CREST, AquaCrest, Aquasu, BBY Essential, Ecoaqua, Filterlogic, Fridgetastic, HDX, INSIGNIA, Kohler, Maxblue, OverbestReplacement: FMW-2 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 300 gal | IAPMO |
Apec Water Systems2 models
Aqualfo Platinum, Reliance2 models
Aquasana19 modelsBrand check
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| AQ-4000Replacement: AQ-4035 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 450 gal | WQA |
| AQ-5200Replacement: AQ-5200R | Not stated | NSF/ANSI 53 | PFOA, PFOS | 500 gal | WQA |
| AQ-5200 1 6 4Replacement: AQ-C2-R | Under-sink | NSF/ANSI 53 | PFOA, PFOS | 500 gal | WQA |
| AQ-5300Replacement: AQ-5300R | Not stated | NSF/ANSI 53 | PFOA, PFOS | 600 gal | WQA |
| AQ-5300 1 4 5Replacement: AQ-C3-R | Under-sink | NSF/ANSI 53 | PFOA, PFOS | 600 gal | WQA |
| AQ-5300+ 1 4Replacement: AQ-5300+R | Under-sink | NSF/ANSI 53 | PFOA, PFOS | 800 gal | WQA |
| AQ-5300+ 1 8 4Replacement: AQ-C3M-R | Under-sink | NSF/ANSI 53 | PFOA, PFOS | 800 gal | WQA |
| AQ-5300+.NF 1 4Replacement: AQ-5300+R | Not stated | NSF/ANSI 53 | PFOA, PFOS | 800 gal | WQA |
| AQ-6200 1 10 4Replacement: AQ-C2-R | Under-sink | NSF/ANSI 53 | PFOA, PFOS | 500 gal | WQA |
| AQ-6300 1 4 11Replacement: AQ-C3-R | Under-sink | NSF/ANSI 53 | PFOA, PFOS | 600 gal | WQA |
| AQ-6300M 1 4 12Replacement: AQ-C3M-R | Under-sink | NSF/ANSI 53 | PFOA, PFOS | 800 gal | WQA |
| AQ-CWM2-X-Y 1 2 3Replacement: AQ-CWM2-R | Not stated | NSF/ANSI 53 | PFOA, PFOS | 300 gal | WQA |
| AQ-HSRO800-XX1Replacement: AQ-HSRO800-CPP | Not stated | NSF/ANSI 53 | PFOA, PFOS | 320 gal | IAPMO |
| AQ-MF-1Replacement: AQ-MF-1-R | Not stated | NSF/ANSI 53 | PFOA, PFOS | 784 gal | IAPMO |
| AQ-SFRO 7Replacement: AQ-SFRO-S1S3 | Reverse osmosis | NSF/ANSI 53 | PFOA, PFOS | 250 gal | WQA |
| AQ-SFRO2 9Replacement: AQ-SFRO-S1S3 | Reverse osmosis | NSF/ANSI 53 | PFOA, PFOS | 250 gal | WQA |
| EQ-OPTMReplacement: EQ-OPTM-R | Whole house | NSF/ANSI 53 | PFOA, PFOS | 106,750 gal | IAPMO |
| OptimH2O™ AQ-RO-3 1 4Replacement: AQ-RO3-R | Under-sink | NSF/ANSI 53 | PFOA, PFOS | 365 gal | WQA |
| WH-HS 13 14Replacement: WH-HS-R | Whole house | NSF/ANSI 53 | PFOA, PFOS, PFNA, PFHpA, PFHxS | 165,000 gal | WQA |
Aquasential15 models
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| Aqua-CleerReplacement: TD | Not stated | NSF/ANSI 53 | PFOA, PFOS | 1,000 gal | IAPMO |
| Fiberglass IndoorReplacement: N/A | Whole house | NSF/ANSI 53 | Total PFAS | 158,000 gal | WQA |
| Fiberglass Indoor, FrenchReplacement: N/A | Whole house | NSF/ANSI 53 | Total PFAS | 158,000 gal | WQA |
| Fiberglass OutdoorReplacement: N/A | Whole house | NSF/ANSI 53 | Total PFAS | 158,000 gal | WQA |
| Quadra-Hull IndoorReplacement: N/A | Whole house | NSF/ANSI 53 | Total PFAS | 158,000 gal | WQA |
| Quadra-Hull Indoor, FrenchReplacement: N/A | Whole house | NSF/ANSI 53 | Total PFAS | 158,000 gal | WQA |
| Quadra-Hull OutdoorReplacement: N/A | Whole house | NSF/ANSI 53 | Total PFAS | 158,000 gal | WQA |
| ROReplacement: TD 1 | Reverse osmosis | NSF/ANSI 53 | Total PFAS | 1,000 gal | WQA |
| RO (2 yr)Replacement: TD 2 | Reverse osmosis | NSF/ANSI 53 | Total PFAS | 2,000 gal | WQA |
| Smart ROReplacement: TD 1 | Reverse osmosis | NSF/ANSI 53 | Total PFAS | 1,000 gal | WQA |
| Smart RO (2 yr)Replacement: TD 2 | Reverse osmosis | NSF/ANSI 53 | Total PFAS | 2,000 gal | WQA |
| Smart RO (2yr) NitrateReplacement: TD 2 | Reverse osmosis | NSF/ANSI 53 | Total PFAS | 2,000 gal | WQA |
| Smart RO NitrateReplacement: TD 1 | Reverse osmosis | NSF/ANSI 53 | Total PFAS | 1,000 gal | WQA |
| Total Defense System 1Replacement: TD | Not stated | NSF/ANSI 53 | PFOA, PFOS | 1,000 gal | IAPMO |
| US-EZ-4Replacement: RC-EZ-4 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 500 gal | IAPMO |
AquaTru23 modelsBrand check
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| AT100Replacement: 10AT100VF01, 10AT100VFA01 | Reverse osmosis | NSF/ANSI 53 | PFOA, PFOS | 300 gal | IAPMO |
| AT110Replacement: 10AT100VF01, 10AT100VFA01 | Reverse osmosis | NSF/ANSI 53 | PFOA, PFOS | 300 gal | IAPMO |
| AT120Replacement: 10AT100VF01, 10AT100VFA01 | Reverse osmosis | NSF/ANSI 53 | PFOA, PFOS | 300 gal | IAPMO |
| AT130Replacement: 10AT100VF01, 10AT100VFA01 | Reverse osmosis | NSF/ANSI 53 | PFOA, PFOS | 300 gal | IAPMO |
| AT140Replacement: 10AT100VF01, 10AT100VFA01 | Reverse osmosis | NSF/ANSI 53 | PFOA, PFOS | 300 gal | IAPMO |
| AT2000Replacement: AT2003, AT2004 | Countertop | NSF/ANSI 53 | PFOA, PFOS | 600 gal | IAPMO |
| AT2010Replacement: AT2003, AT2004 | Countertop | NSF/ANSI 53 | PFOA, PFOS | 600 gal | IAPMO |
| AT2020Replacement: AT2003, AT2004 | Countertop | NSF/ANSI 53 | PFOA, PFOS | 600 gal | IAPMO |
| AT2030Replacement: AT2003, AT2004 | Countertop | NSF/ANSI 53 | PFOA, PFOS | 600 gal | IAPMO |
| AT2040Replacement: AT2003, AT2004 | Countertop | NSF/ANSI 53 | PFOA, PFOS | 600 gal | IAPMO |
| AT2050Replacement: AT2003, AT2004 | Countertop | NSF/ANSI 53 | PFOA, PFOS | 600 gal | IAPMO |
| ATFS-1-WReplacement: AT2003, AT2004 | Reverse osmosis | NSF/ANSI 53 | PFOA, PFOS | 600 gal | IAPMO |
| ATFS-3-WReplacement: AT2003, ATFS-M | Reverse osmosis | NSF/ANSI 53 | PFOA, PFOS | 1,200 gal | IAPMO |
| ATFS-3-W-AReplacement: AT2003, ATFS-M | Reverse osmosis | NSF/ANSI 53 | PFOA, PFOS | 1,200 gal | IAPMO |
| ATFS-3-W-BReplacement: AT2003, ATFS-M | Reverse osmosis | NSF/ANSI 53 | PFOA, PFOS | 1,200 gal | IAPMO |
| ATFS-3-W-CReplacement: AT2003, ATFS-M | Reverse osmosis | NSF/ANSI 53 | PFOA, PFOS | 1,200 gal | IAPMO |
| ATFS-3-W-DReplacement: AT2003, ATFS-M | Reverse osmosis | NSF/ANSI 53 | PFOA, PFOS | 1,200 gal | IAPMO |
| ATFS-3-W-EReplacement: AT2003, ATFS-M | Reverse osmosis | NSF/ANSI 53 | PFOA, PFOS | 1,200 gal | IAPMO |
| ATU100Replacement: ATU2003, ATU2004 | Under-sink | NSF/ANSI 53 | PFOA, PFOS | 360 gal | IAPMO |
| ATU200Replacement: ATU2003, ATU2004 | Under-sink | NSF/ANSI 53 | PFOA, PFOS | 360 gal | IAPMO |
| ATW-1-FACReplacement: ATW1-F1 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 3,000 gal | IAPMO |
| ATW-1-FBACReplacement: ATW1-F1 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 3,000 gal | IAPMO |
| ATW-1-FBLACReplacement: ATW1-F1 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 3,000 gal | IAPMO |
AzurAqua1 model
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| AA-WP-049Replacement: AA-WF-031 | Pitcher | NSF/ANSI 53 | PFOA, PFOS | 20 gal | IAPMO |
Bosch2 models
Brio12 models
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| FUS100A11SSReplacement: RPFFUS100SS11 | Not stated | NSF/ANSI 53 | Total PFAS | 825 gal | NSF |
| FUS100A16SSReplacement: RPFFUS100SS16 | Not stated | NSF/ANSI 53 | Total PFAS | 1,200 gal | NSF |
| FUS100A22SSReplacement: RPFFUS100SS22 | Not stated | NSF/ANSI 53 | Total PFAS | 1,650 gal | NSF |
| FUS100A26SSReplacement: RPFFUS100SS26 | Not stated | NSF/ANSI 53 | Total PFAS | 1,950 gal | NSF |
| FUS100F11SSReplacement: RPFFUS100SS11 | Under-sink | NSF/ANSI 53 | Total PFAS | 825 gal | NSF |
| FUS100F16SSReplacement: RPFFUS100SS16 | Under-sink | NSF/ANSI 53 | Total PFAS | 1,200 gal | NSF |
| FUS100F22SSReplacement: RPFFUS100SS22 | Under-sink | NSF/ANSI 53 | Total PFAS | 1,650 gal | NSF |
| FUS100F26SSReplacement: RPFFUS100SS26 | Under-sink | NSF/ANSI 53 | Total PFAS | 1,950 gal | NSF |
| RPFFUS100SS11 | Other | NSF/ANSI 53 | Total PFAS | 825 gal | NSF |
| RPFFUS100SS16 | Other | NSF/ANSI 53 | Total PFAS | 1,200 gal | NSF |
| RPFFUS100SS22 | Other | NSF/ANSI 53 | Total PFAS | 1,650 gal | NSF |
| RPFFUS100SS26 | Other | NSF/ANSI 53 | Total PFAS | 1,950 gal | NSF |
Brita1 model
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| BUSS01Replacement: BUSF01 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 660 gal | IAPMO |
Brita Pro1 model
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| BP150NJ | Whole house | NSF/ANSI 53 | Total PFAS | 1,766 gal | IAPMO |
Brizo2 models
Brondell3 models
Campbell6 models
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| ULTF4PLUS 1Replacement: ULTF4-FILTER1, ULTF4-FILTER2, ULTF4-FILTER3 | Whole house | NSF/ANSI 53 | Total PFAS | 25,000 gal | IAPMO |
| ULTF4PLUS-PID 1Replacement: ULTF4-FILTER1, ULTF4-FILTER2, ULTF4-FILTER3 | Whole house | NSF/ANSI 53 | Total PFAS | 42,857 gal | IAPMO |
| ULTFILTR10PLUS 1Replacement: UTLF10-FILTER1, UTLF10-FILTER2, UTLF10-FILTER3 | Whole house | NSF/ANSI 53 | Total PFAS | 6,000 gal | IAPMO |
| ULTFILTR20PLUS 1Replacement: UTLF20-FILTER1, UTLF20-FILTER2, UTLF20-FILTER3 | Whole house | NSF/ANSI 53 | Total PFAS | 12,000 gal | IAPMO |
| ULTSQBOTTLE 1Replacement: ULTSQFILTER | Bottle | NSF/ANSI 53 | Total PFAS | 25 gal | IAPMO |
| ULTUNDERSINK 1Replacement: ULTUNDERSINKFLT | Not stated | NSF/ANSI 53 | PFOA, PFOS | 150 gal | IAPMO |
Caware24 models
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| YYY-095MC-S7Replacement: YYY-095MCS | Not stated | NSF/ANSI 53 | Total PFAS | 9460 liters gal | IAPMO |
| YYY-095WM-S 3Replacement: YYY-095WM | Not stated | NSF/ANSI 53 | Total PFAS | 9460 liters gal | IAPMO |
| YYY-10EP-S 3Replacement: YYY-10EP | Not stated | NSF/ANSI 53 | Total PFAS | 9460 liters gal | IAPMO |
| YYY-10EV-S7Replacement: YYY-10EV | Not stated | NSF/ANSI 53 | Total PFAS | 9460 liters gal | IAPMO |
| YYY-13MD-S 3Replacement: YYY-13MD | Not stated | NSF/ANSI 53 | Total PFAS | 11355 liters gal | IAPMO |
| YYY-14ECO-S 3Replacement: YYY-14ECO | Not stated | NSF/ANSI 53 | Total PFAS | 11355 liters gal | IAPMO |
| YYY-14EP-S 3Replacement: YYY-14EP | Not stated | NSF/ANSI 53 | Total PFAS | 11355 liters gal | IAPMO |
| YYY-14EV-S7Replacement: YYY-14EV | Not stated | NSF/ANSI 53 | Total PFAS | 22710 liters gal | IAPMO |
| YYY-14MCS-S7Replacement: YYY-14MCS | Not stated | NSF/ANSI 53 | Total PFAS | 22710 liters gal | IAPMO |
| YYY-14WM-S3Replacement: YYY-14WM | Not stated | NSF/ANSI 53 | Total PFAS | 22710 liters gal | IAPMO |
| YYY-14XEP-S 3Replacement: YYY-14XEP | Not stated | NSF/ANSI 53 | Total PFAS | 8325 liters gal | IAPMO |
| YYY-20EP-S 3Replacement: YYY-20EP | Not stated | NSF/ANSI 53 | Total PFAS | 22710 liters gal | IAPMO |
| ZZZ-095MCS-S8Replacement: ZZZ-095MCS | Not stated | NSF/ANSI 53 | Total PFAS | 9460 liters gal | IAPMO |
| ZZZ-095WM-S 4Replacement: ZZZ-095WM | Not stated | NSF/ANSI 53 | Total PFAS | 9460 liters gal | IAPMO |
| ZZZ-10EP-S 4Replacement: ZZZ-10EP | Not stated | NSF/ANSI 53 | Total PFAS | 9460 liters gal | IAPMO |
| ZZZ-10EV-S8Replacement: ZZZ-10EV | Not stated | NSF/ANSI 53 | Total PFAS | 9460 liters gal | IAPMO |
| ZZZ-13MD-S 4Replacement: ZZZ-13MD | Not stated | NSF/ANSI 53 | Total PFAS | 11355 liters gal | IAPMO |
| ZZZ-14ECO-S 4Replacement: ZZZ-14ECO | Not stated | NSF/ANSI 53 | Total PFAS | 11355 liters gal | IAPMO |
| ZZZ-14EP-S 4Replacement: ZZZ-14EP | Not stated | NSF/ANSI 53 | Total PFAS | 11355 liters gal | IAPMO |
| ZZZ-14EV-S8Replacement: ZZZ-14EV | Not stated | NSF/ANSI 53 | Total PFAS | 22710 liters gal | IAPMO |
| ZZZ-14MCS-S8Replacement: ZZZ-14MCS | Not stated | NSF/ANSI 53 | Total PFAS | 22710 liters gal | IAPMO |
| ZZZ-14WM-S 4Replacement: ZZZ-14WM | Not stated | NSF/ANSI 53 | Total PFAS | 22710 liters gal | IAPMO |
| ZZZ-14XEP-S 4Replacement: ZZZ-14XEP | Not stated | NSF/ANSI 53 | Total PFAS | 8325 liters gal | IAPMO |
| ZZZ-20EP-S 4Replacement: ZZZ-20EP | Not stated | NSF/ANSI 53 | Total PFAS | 22710 liters gal | IAPMO |
Coway32 models
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| AqualityReplacement: CCNTN7W-A-LR | Under-sink | NSF/ANSI 53 | PFOA, PFOS | 1135 liters gal | IAPMO |
| CHP-1112NReplacement: CCNTN7W-A-LR | Under-sink | NSF/ANSI 53 | PFOA, PFOS | 300 gal | IAPMO |
| CHP-1300LReplacement: CCFN8S-POST-PLUS | Not stated | NSF/ANSI 53 | Total PFAS | 165 gal | WQA |
| CHP-1300LReplacement: CRMFN8S-20D-N2 | Reverse osmosis | NSF/ANSI 58 | PFOA, PFOS | WQA | |
| CHP-264LReplacement: CRMFN8S-20 | Reverse osmosis | NSF/ANSI 58 | PFOA, PFOS | WQA | |
| CHP-5700RReplacement: CCRMFN12-D-600 | Reverse osmosis | NSF/ANSI 58 | PFOA, PFOS | WQA | |
| CHP-6220NReplacement: CCNTN7W-A-LR | Under-sink | NSF/ANSI 53 | PFOA, PFOS | 300 gal | IAPMO |
| CHP-6310LReplacement: CRMFN8S-20-N2 | Reverse osmosis | NSF/ANSI 58 | PFOA, PFOS | WQA | |
| CHP-6330LReplacement: CRMFN8S-20 | Reverse osmosis | NSF/ANSI 58 | PFOA, PFOS | WQA | |
| CHP-6340LReplacement: CRMFN8S-20 | Reverse osmosis | NSF/ANSI 58 | PFOA, PFOS | WQA | |
| CHP-7310RReplacement: CRMFN8S-20 | Reverse osmosis | NSF/ANSI 58 | PFOA, PFOS | WQA | |
| CHP-7320LReplacement: CRMFN8S-20-N2 | Reverse osmosis | NSF/ANSI 58 | PFOA, PFOS | WQA | |
| CHP-7320RReplacement: CRMFN8S-20-N2 | Reverse osmosis | NSF/ANSI 58 | PFOA, PFOS | WQA | |
| CHPI-1500LReplacement: CCFN8S-POST-PLUS | Reverse osmosis | NSF/ANSI 53 | Total PFAS | 165 gal | WQA |
| CHPI-1500LReplacement: CRMFN8S-20-D-N2 | Reverse osmosis | NSF/ANSI 58 | PFOA, PFOS | WQA | |
| CHPI-280LReplacement: CRMFN8S-20 | Reverse osmosis | NSF/ANSI 58 | PFOA, PFOS | WQA | |
| CHPI-7410NReplacement: CCNTN7W-A-LR | Under-sink | NSF/ANSI 53 | PFOA, PFOS | 300 gal | IAPMO |
| CHPI-7413NReplacement: CCNTN7W-A-LR | Under-sink | NSF/ANSI 53 | PFOA, PFOS | 300 gal | IAPMO |
| CHPI-7420NReplacement: CCNTN7W-A-LR | Under-sink | NSF/ANSI 53 | PFOA, PFOS | 300 gal | IAPMO |
| CHPI-7511LReplacement: CRMFN8S-20-N2 | Reverse osmosis | NSF/ANSI 58 | PFOA, PFOS | WQA | |
| CHPI-7520LReplacement: CRMFN8S-20-N2 | Reverse osmosis | NSF/ANSI 58 | PFOA, PFOS | WQA | |
| CHPI-7521LReplacement: CRMFN8S-20-N2 | Reverse osmosis | NSF/ANSI 58 | PFOA, PFOS | WQA | |
| CP-6310LReplacement: CRMFN8S-20-N2 | Reverse osmosis | NSF/ANSI 58 | PFOA, PFOS | WQA | |
| CP-6330LReplacement: CRMFN8S-20 | Reverse osmosis | NSF/ANSI 58 | PFOA, PFOS | WQA | |
| CP-6340LReplacement: CRMFN8S-20 | Reverse osmosis | NSF/ANSI 58 | PFOA, PFOS | WQA | |
| CPI-7410NReplacement: CCNTN7W-A-LR | Under-sink | NSF/ANSI 53 | PFOA, PFOS | 300 gal | IAPMO |
| CPI-7413NReplacement: CCNTN7W-A-LR | Under-sink | NSF/ANSI 53 | PFOA, PFOS | 300 gal | IAPMO |
| CPI-7511LReplacement: CRMFN8S-20-N2 | Reverse osmosis | NSF/ANSI 58 | PFOA, PFOS | WQA | |
| CPSI-8510LReplacement: CRMFN8S-20-N2 | Reverse osmosis | NSF/ANSI 58 | PFOA, PFOS | WQA | |
| P-2201NReplacement: CCNTN7W-A-LR | Under-sink | NSF/ANSI 53 | PFOA, PFOS | 1135 liters gal | IAPMO |
| P-2211NReplacement: CCNTN7W-A-LR | Under-sink | NSF/ANSI 53 | PFOA, PFOS | 1135 liters gal | IAPMO |
| P-300L(US)Replacement: CRMFN8S-20 | Reverse osmosis | NSF/ANSI 58 | PFOA, PFOS | WQA |
Culligan22 models
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| Ascent 100-ROReplacement: BFC-RO80; BFC-PRE and BFC-RO80 | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO | |
| Ascent 40-ROReplacement: BFC-RO80; BFC-PRE and BFC-RO80 | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO | |
| Ascent 80-ROReplacement: BFC-RO80; BFC-PRE and BFC-RO80 | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO | |
| Ascent CT-ROReplacement: BFC-RO80; BFC-PRE and BFC-RO80 | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO | |
| CFM-300CRReplacement: CRFM-001 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 300 gal | WQA |
| CFM-300WH | Not stated | NSF/ANSI 53 | PFOA, PFOS | 300 gal | WQA |
| CUGMW-CSReplacement: CUGMW | Refrigerator filter | NSF/ANSI 53 | PFOA, PFOS | 300 gal | IAPMO |
| CULFMCHReplacement: CULFMF01 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 400 gal | WQA |
| CULFMWHReplacement: CULFMF01 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 400 gal | WQA |
| IC-EZ-41Replacement: RC-EZ-4 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 500 gal | IAPMO |
| US-DC4Replacement: US-DC4-R | Not stated | NSF/ANSI 53 | PFOA, PFOS | 651 gal | IAPMO |
| US-EZ-41Replacement: RC-EZ-4 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 500 gal | IAPMO |
| ZEROD22Replacement: ZEROFXX1 | Pitcher | NSF/ANSI 53 | Total PFAS | 20 gal | IAPMO |
| ZEROD23Replacement: ZEROFXX1 | Pitcher | NSF/ANSI 53 | Total PFAS | 20 gal | IAPMO |
| ZEROD32Replacement: ZEROFXX1 | Pitcher | NSF/ANSI 53 | Total PFAS | 20 gal | IAPMO |
| ZEROD33Replacement: ZEROFXX1 | Pitcher | NSF/ANSI 53 | Total PFAS | 20 gal | IAPMO |
| ZEROD40Replacement: ZEROFXX1 | Pitcher | NSF/ANSI 53 | Total PFAS | 20 gal | IAPMO |
| ZEROD52Replacement: ZEROFXX1 | Pitcher | NSF/ANSI 53 | Total PFAS | 40 gal | IAPMO |
| ZEROP07Replacement: ZEROFXX1 | Pitcher | NSF/ANSI 53 | Total PFAS | 20 gal | IAPMO |
| ZEROP08Replacement: ZEROFXX1 | Pitcher | NSF/ANSI 53 | Total PFAS | 20 gal | IAPMO |
| ZEROP10Replacement: ZEROFXX1 | Pitcher | NSF/ANSI 53 | Total PFAS | 20 gal | IAPMO |
| ZEROP12Replacement: ZEROFXX1 | Pitcher | NSF/ANSI 53 | Total PFAS | 20 gal | IAPMO |
Culligan Korea29 models
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| 3iRReplacement: EN1100-0004 | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO | |
| Ascent 100-ROReplacement: CG-QC3R; CG-QC2 and CG-QC3R | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO | |
| Ascent 40-ROReplacement: CG-QC3R; CG-QC2 and CG-QC3R | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO | |
| Ascent 80-ROReplacement: CG-QC3R; CG-QC2 and CG-QC3R | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO | |
| Ascent CT-ROReplacement: CG-QC3R; CG-QC2 and CG-QC3R | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO | |
| OS2-RO1Replacement: OS-QC2 and OS-QC3R | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO | |
| OS2CT-RO1Replacement: OS-QC2 and OS-QC3R | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO | |
| PW50RReplacement: EN1100-0004 | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO | |
| PW70RReplacement: EN1100-0004 | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO | |
| PW90RReplacement: EN1100-0004 | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO | |
| Q3FSReplacement: HF-EX3R; HF-EX2 and HF-EX3R | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO | |
| Q4FSReplacement: HF-EX3R; HF-EX2 and HF-EX3R | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO | |
| Q5CTReplacement: HF-EX3R; HF-EX2 and HF-EX3R | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO | |
| Q5CTEReplacement: HF-EX3R; HF-EX2 and HF-EX3R | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO | |
| Q5FSReplacement: HF-EX3R1; HF-EX2 and HF-EX3R1 | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO | |
| Q5FS3Replacement: HF-EX3R; HF-EX2 and HF-EX3R | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO | |
| Q7CTReplacement: HF-EX3R; HF-EX2 and HF-EX3R | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO | |
| Q7CTEReplacement: HF-EX3R; HF-EX2 and HF-EX3R | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO | |
| Q7FSReplacement: HF-EX3R; HF-EX2 and HF-EX3R | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO | |
| Q8CTReplacement: HF-EX3R; HF-EX2 and HF-EX3R | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO | |
| Q8CTEReplacement: HF-EX3R; HF-EX2 and HF-EX3R | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO | |
| Q8FSReplacement: HF-EX3R; HF-EX2 and HF-EX3R | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO | |
| W5-ROReplacement: WS-QC3R; WS-QC2 and WS-QC3R | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO | |
| W7-ROReplacement: WS-QC3R; WS-QC2 and WS-QC3R | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO | |
| W9-ROReplacement: WS-QC3R; WS-QC2 and WS-QC3R | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO | |
| W9CT-ROReplacement: WS-QC3R; WS-QC2 and WS-QC3R | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO | |
| WL30-ROReplacement: RO Membrane: WLRO-12 Filter and RO Membrane: WLPC-12 and WLRO-13 | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO | |
| WL50-ROReplacement: RO Membrane: WLRO-12 Filter and RO Membrane: WLPC-12 and WLRO-12 | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO | |
| WLCT-ROReplacement: RO Membrane: WLRO-12 Filter and RO Membrane: WLPC-12 and WLRO-14 | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO |
Delta5 models
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| DFS-1000Replacement: DFC-100PP, DFC-100CB | Not stated | NSF/ANSI 53 | PFOA, PFOS | 700 gal | IAPMO |
| DUFS-C1-UF3-4A 1, 3Replacement: DUFM-C1-UFD-4N | Not stated | NSF/ANSI 53 | PFOA, PFOS | 1,100 gal | IAPMO |
| DWQ1001012Replacement: DWQ300102 | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO | |
| DWQ1001012Replacement: DWQ300202 | Reverse osmosis | NSF/ANSI 53 | Total PFAS | 1,320 gal | IAPMO |
| DWQ3502020 1, 2Replacement: DWQ300700 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 1,100 gal | IAPMO |
Eclipse8 models
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| C6500Also sold as WaterChefReplacement: CR65 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 600 gal | IAPMO |
| C7500Also sold as WaterChefReplacement: CR75 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 1,000 gal | IAPMO |
| CT-35EAlso sold as WaterChefReplacement: RC-35E | Not stated | NSF/ANSI 53 | PFOA, PFOS | 1,000 gal | IAPMO |
| U85001Also sold as WaterChefReplacement: UR85 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 600 gal | IAPMO |
| U8500HO1Also sold as WaterChefReplacement: UR85 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 600 gal | IAPMO |
| U90001Also sold as WaterChefReplacement: UR90 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 1,000 gal | IAPMO |
| UC-45Also sold as WaterChefReplacement: RC-45 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 600 gal | IAPMO |
| UC-45EAlso sold as WaterChefReplacement: RC-45E | Not stated | NSF/ANSI 53 | PFOA, PFOS | 1,000 gal | IAPMO |
Ecopure1 model
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| EPWPFFReplacement: EPWPRF | Not stated | NSF/ANSI 53 | PFOA, PFOS | 660 gal | IAPMO |
EcoWater4 models
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| EAFF-1004Replacement: 7391745 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 660 gal | IAPMO |
| ERO-385-xx1, 2Replacement: 7397301, 7382762 | Reverse osmosis | NSF/ANSI 58 | PFOA, PFOS | IAPMO | |
| ERO-385E-xx1, 2Replacement: 7397301, 7382762 | Reverse osmosis | NSF/ANSI 58 | PFOA, PFOS | IAPMO | |
| HERO-385PLUS-xx1, 2Replacement: 7397301, 7382762 | Reverse osmosis | NSF/ANSI 58 | PFOA, PFOS | IAPMO |
Elkay2 models
eSpring (Amway)34 models
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| 100186XReplacement: N/A | Countertop | NSF/ANSI 53 | PFOA, PFOS | 1,320 gal | NSF |
| 122940CH 2Replacement: 122943XX | Not stated | NSF/ANSI 53 | PFOA, PFOS | 1,320 gal | WQA |
| 122940XX 6Replacement: 122943XX | Not stated | NSF/ANSI 53 | PFOA, PFOS | 1,320 gal | WQA |
| 122941CH 3Replacement: 122943XX | Under-sink | NSF/ANSI 53 | PFOA, PFOS | 1,320 gal | WQA |
| 122941XX 7Replacement: 122943XX | Under-sink | NSF/ANSI 53 | PFOA, PFOS | 1,320 gal | WQA |
| CXV5764Replacement: N/A | Countertop | NSF/ANSI 53 | PFOA, PFOS | 1,320 gal | NSF |
| CXV6425Replacement: N/A | Countertop | NSF/ANSI 53 | PFOA, PFOS | 1,320 gal | NSF |
| eSpring 122940Replacement: 122943 | Countertop | NSF/ANSI 53 | PFOA, PFOS, Total PFAS | 1,320 gal | NSF |
| eSpring 122940 INReplacement: 122943Z | Countertop | NSF/ANSI 53 | PFOA, PFOS, Total PFAS | 1,320 gal | NSF |
| eSpring 122940CReplacement: 122943 | Countertop | NSF/ANSI 53 | PFOA, PFOS, Total PFAS | 1,320 gal | NSF |
| eSpring 122940CAReplacement: 122943 | Countertop | NSF/ANSI 53 | PFOA, PFOS, Total PFAS | 1,320 gal | NSF |
| eSpring 122940CHReplacement: 122943Z | Countertop | NSF/ANSI 53 | PFOA, PFOS, Total PFAS | 1,320 gal | NSF |
| eSpring 122940HKReplacement: 122943Z | Countertop | NSF/ANSI 53 | PFOA, PFOS, Total PFAS | 1,320 gal | NSF |
| eSpring 122940JReplacement: 122943Z | Countertop | NSF/ANSI 53 | PFOA, PFOS, Total PFAS | 1,320 gal | NSF |
| eSpring 122940KReplacement: 122943Z | Countertop | NSF/ANSI 53 | PFOA, PFOS, Total PFAS | 1,320 gal | NSF |
| eSpring 122940MReplacement: 122943M | Countertop | NSF/ANSI 53 | PFOA, PFOS, Total PFAS | 1,320 gal | NSF |
| eSpring 122940SGReplacement: 122943M | Countertop | NSF/ANSI 53 | PFOA, PFOS, Total PFAS | 1,320 gal | NSF |
| eSpring 122940TReplacement: 122943T | Countertop | NSF/ANSI 53 | PFOA, PFOS, Total PFAS | 1,320 gal | NSF |
| eSpring 122940THReplacement: 122943Z | Countertop | NSF/ANSI 53 | PFOA, PFOS, Total PFAS | 1,320 gal | NSF |
| eSpring 122941Replacement: 122943 | Under-sink | NSF/ANSI 53 | PFOA, PFOS, Total PFAS | 1,320 gal | NSF |
| eSpring 122941CReplacement: 122943 | Under-sink | NSF/ANSI 53 | PFOA, PFOS, Total PFAS | 1,320 gal | NSF |
| eSpring 122941CAReplacement: 122943 | Under-sink | NSF/ANSI 53 | PFOA, PFOS, Total PFAS | 1,320 gal | NSF |
| eSpring 122941CHReplacement: 122943Z | Under-sink | NSF/ANSI 53 | PFOA, PFOS, Total PFAS | 1,320 gal | NSF |
| eSpring 122941JReplacement: 122943Z | Under-sink | NSF/ANSI 53 | PFOA, PFOS, Total PFAS | 1,320 gal | NSF |
| eSpring 122941KReplacement: 122943Z | Under-sink | NSF/ANSI 53 | PFOA, PFOS, Total PFAS | 1,320 gal | NSF |
| eSpring 122941TReplacement: 122943T | Under-sink | NSF/ANSI 53 | PFOA, PFOS, Total PFAS | 1,320 gal | NSF |
| eSpring 128212XYReplacement: 122943 | Under-sink | NSF/ANSI 53 | PFOA, PFOS, Total PFAS | 1,320 gal | NSF |
| eSpring Model 100188CHReplacement: 100186CH,K, T, TH, M, J, ME | Countertop | NSF/ANSI 53 | PFOA, PFOS | 1,320 gal | NSF |
| eSpring Model 100189CHReplacement: 100186CH | Under-sink | NSF/ANSI 53 | PFOA, PFOS | 1,320 gal | NSF |
| eSpring Model 122940CHReplacement: 122943CH | Countertop | NSF/ANSI 53 | PFOA, PFOS, Total PFAS | 1,320 gal | NSF |
| eSpring Model 122940VNReplacement: 122943Z | Countertop | NSF/ANSI 53 | PFOA, PFOS, Total PFAS | 1,320 gal | NSF |
| eSpring Model 122941CHReplacement: 122943CH | Under-sink | NSF/ANSI 53 | PFOA, PFOS, Total PFAS | 1,320 gal | NSF |
| eSpring Model 122941VNReplacement: 122943Z | Under-sink | NSF/ANSI 53 | PFOA, PFOS, Total PFAS | 1,320 gal | NSF |
| eSpring WTI1167XReplacement: N/A | Countertop | NSF/ANSI 53 | PFOA, PFOS, Total PFAS | 1,320 gal | NSF |
Everpure8 models
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| H-1200 1Replacement: H-1200 #1, H-1200 #2 | Under-sink | NSF/ANSI 53 | Total PFAS | 1,000 gal | IAPMO |
| MRS-600HE-II-PReplacement: 7FC-P | Under-sink | NSF/ANSI 53 | PFOA, PFOS | 20,000 gal | IAPMO |
| QL3B - 2FC-PReplacement: 2FC-P | Not stated | NSF/ANSI 53 | PFOA, PFOS | 1,000 gal | IAPMO |
| QL3B - 2FC-PSReplacement: 2FC-PS | Not stated | NSF/ANSI 53 | PFOA, PFOS | 1,000 gal | IAPMO |
| QL3B - 4FC-PReplacement: 4FC-P | Not stated | NSF/ANSI 53 | PFOA, PFOS | 4,000 gal | IAPMO |
| QL3B - 4FC-PSReplacement: 4FC-PS | Not stated | NSF/ANSI 53 | PFOA, PFOS | 4,000 gal | IAPMO |
| QL3B - 7FC-PReplacement: 7FC-P | Not stated | NSF/ANSI 53 | PFOA, PFOS | 10,000 gal | IAPMO |
| QL3B - 7FC-PSReplacement: 7FC-PS | Not stated | NSF/ANSI 53 | PFOA, PFOS | 10,000 gal | IAPMO |
Express Water1 model
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| USC001Replacement: FLTUSC001 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 1,500 gal | IAPMO |
Filtertech2 models
FLUUX8 models
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| FPO-10Replacement: FPO-10R | Not stated | NSF/ANSI 53 | PFOA, PFOS | 1,500 gal | IAPMO |
| FPO-10SReplacement: FPO-10SR | Not stated | NSF/ANSI 53 | PFOA, PFOS | 1,500 gal | IAPMO |
| FPO-15Replacement: FPO-15R | Not stated | NSF/ANSI 53 | PFOA, PFOS | 2,640 gal | IAPMO |
| FPO-15SReplacement: FPO-15SR | Not stated | NSF/ANSI 53 | PFOA, PFOS | 2,640 gal | IAPMO |
| FPO-17Replacement: FPO-17R | Not stated | NSF/ANSI 53 | PFOA, PFOS | 3,240 gal | IAPMO |
| FPO-17SReplacement: FPO-17SR | Not stated | NSF/ANSI 53 | PFOA, PFOS | 3,240 gal | IAPMO |
| FPO-21Replacement: FPO-21R | Not stated | NSF/ANSI 53 | PFOA, PFOS | 4,140 gal | IAPMO |
| FPO-21SReplacement: FPO-21SR | Not stated | NSF/ANSI 53 | PFOA, PFOS | 4,140 gal | IAPMO |
FrescaPure3 models
Frigidaire7 models
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| PureAdvantage PWF-1Replacement: EPPWFU01 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 125 gal | IAPMO |
| PureAdvantage PWF-2Replacement: EPPWFU02 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 125 gal | IAPMO |
| PureAdvantage UltraReplacement: EWF02 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 125 gal | IAPMO |
| PurePour Connect PWF-2Replacement: FPPWFU02 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 125 gal | IAPMO |
| PurePour PWF-1Replacement: FPPWFU01 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 125 gal | IAPMO |
| PurePour WFPTReplacement: WFPTU26 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 125 gal | IAPMO |
| PureSource Ultra IIReplacement: EPTWFU01 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 125 gal | IAPMO |
GE Appliances17 models
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| EQW-1Also sold as A HAIER COMPANYReplacement: EQW-1 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 200 gal | IAPMO |
| EQW-3Also sold as A HAIER COMPANYReplacement: EQW-3 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 200 gal | IAPMO |
| FML-5Also sold as A HAIER COMPANYReplacement: FML-5 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 200 gal | IAPMO |
| FMM-2Also sold as A HAIER COMPANYReplacement: FMM-2 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 200 gal | IAPMO |
| FMS-2Also sold as A HAIER COMPANYReplacement: FMS-2 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 300 gal | IAPMO |
| FMS-4Also sold as A HAIER COMPANYReplacement: FMS-4 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 300 gal | IAPMO |
| GNRQ18NBNAlso sold as A HAIER COMPANYReplacement: FQ18MN,FQ18PN | Reverse osmosis | NSF/ANSI 58 | PFOA, PFOS | IAPMO | |
| GXK140TNNAlso sold as A HAIER COMPANYReplacement: FQK1R | Not stated | NSF/ANSI 53 | PFOA, PFOS | 1,500 gal | IAPMO |
| GXRV40TBNAlso sold as A HAIER COMPANYReplacement: FQ18MN,FQ18PN | Reverse osmosis | NSF/ANSI 58 | PFOA, PFOS | IAPMO | |
| MWF1Also sold as A HAIER COMPANYReplacement: MWF | Refrigerator filter | NSF/ANSI 53 | PFOA, PFOS | 170 gal | IAPMO |
| PSCIN-CSAlso sold as A HAIER COMPANYReplacement: PSCIN | Not stated | NSF/ANSI 53 | PFOA, PFOS | 300 gal | IAPMO |
| PSL1000-CSAlso sold as A HAIER COMPANYReplacement: PSL1000 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 200 gal | IAPMO |
| PSQQIN-CSAlso sold as A HAIER COMPANYReplacement: PSQIN | Not stated | NSF/ANSI 53 | PFOA, PFOS | 300 gal | IAPMO |
| PSW1-CSAlso sold as A HAIER COMPANYReplacement: PSW1 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 200 gal | IAPMO |
| PSW3-CSAlso sold as A HAIER COMPANYReplacement: PSW3 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 200 gal | IAPMO |
| PSW4-CSAlso sold as A HAIER COMPANYReplacement: PSW4 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 200 gal | IAPMO |
| ZWFEAlso sold as A HAIER COMPANYReplacement: ZWFE | Refrigerator filter | NSF/ANSI 53 | Total PFAS | 170 gal | IAPMO |
Global Industrial2 models
Greenpan4 models
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| CC010365-003Replacement: CC010718-003 | Pitcher | NSF/ANSI 53 | Total PFAS | 30 gal | IAPMO |
| CC010721-003Replacement: CC010718-003 | Pitcher | NSF/ANSI 53 | Total PFAS | 30 gal | IAPMO |
| CC010722-003Replacement: CC010718-003 | Pitcher | NSF/ANSI 53 | Total PFAS | 30 gal | IAPMO |
| CC011733-003Replacement: CC010718-003 | Pitcher | NSF/ANSI 53 | Total PFAS | 30 gal | IAPMO |
Halo Defender Ii11 model
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| H-DFR2-STALReplacement: H-DFR2-PFLD | Not stated | NSF/ANSI 53 | PFOA, PFOS | 93,250 gal | IAPMO |
HDX7 models
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| EQG-2-CSReplacement: EQG-2 | Refrigerator filter | NSF/ANSI 53 | PFOA, PFOS | 170 gal | IAPMO |
| FMF-8-CSReplacement: FMF-8 | Refrigerator filter | NSF/ANSI 53 | PFOA, PFOS | 200 gal | IAPMO |
| FML-1-CSReplacement: FML-1 | Refrigerator filter | NSF/ANSI 53 | PFOA, PFOS | 300 gal | IAPMO |
| FML-3-CSReplacement: FML-3 | Refrigerator filter | NSF/ANSI 53 | PFOA, PFOS | 200 gal | IAPMO |
| FML-4-CSReplacement: FML-4 | Refrigerator filter | NSF/ANSI 53 | PFOA, PFOS | 200 gal | IAPMO |
| FMS-1-CSReplacement: FMS-1 | Refrigerator filter | NSF/ANSI 53 | PFOA, PFOS | 300 gal | IAPMO |
| FMW-2-CSReplacement: FMW-2 | Refrigerator filter | NSF/ANSI 53 | PFOA, PFOS | 240 gal | IAPMO |
Hydroviv8 models
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| Hydroviv Drinking Water SystemReplacement: HYDROVIV-US-REP-19oZIP | Not stated | NSF/ANSI 53 | Total PFAS | 500 gal | IAPMO |
| HYDROVIV-US-SRS-14cZIPReplacement: HYDROVIV-US-REP-14cZIP | Not stated | NSF/ANSI 53 | PFOA, PFOS | 360 gal | IAPMO |
| HYDROVIV-US-SRS-18pZIPReplacement: HYDROVIV-US-REP-18pZIP | Not stated | NSF/ANSI 53 | PFOA, PFOS | 450 gal | IAPMO |
| HYDROVIV-US-SRS-43pZIPReplacement: HYDROVIV-US-REP-43pZIP | Not stated | NSF/ANSI 53 | PFOA, PFOS | 450 gal | IAPMO |
| HYDROVIV-US-SRS-46cZIPReplacement: HYDROVIV-US-REP-46cZIP | Not stated | NSF/ANSI 53 | PFOA, PFOS | 360 gal | IAPMO |
| HYDROVIV-US-SRS-71xZIPReplacement: HYDROVIV-US-REP-71xZIP | Not stated | NSF/ANSI 53 | PFOA, PFOS | 600 gal | IAPMO |
| HYDROVIV-US-SRS-74pZIPReplacement: HYDROVIV-US-REP-74pZIP | Not stated | NSF/ANSI 53 | PFOA, PFOS | 450 gal | IAPMO |
| HYDROVIV-US-SRS-75cZIPReplacement: HYDROVIV-US-REP-75cZIP | Not stated | NSF/ANSI 53 | PFOA, PFOS | 360 gal | IAPMO |
IEQ Solutions1 model
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| HWS6Replacement: HWS6R | Not stated | NSF/ANSI 53 | Total PFAS | 3,000 gal | IAPMO |
Infinity Protector1 model
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| INF-PRO1Replacement: INF-PRO1-FX | Whole house | NSF/ANSI 53 | PFOA, PFOS | 100,000 gal | IAPMO |
InSinkErator6 models
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| F-1000S1Replacement: F-3000 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 500 gal | IAPMO |
| F-2000S1Replacement: F-3000 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 500 gal | IAPMO |
| F-3000S1Replacement: F-3000 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 500 gal | IAPMO |
| HWT-F1000S1Replacement: F-3000 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 500 gal | IAPMO |
| HWT200-F2000S1Replacement: F-3000 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 500 gal | IAPMO |
| HWT300-F3000S1Replacement: F-3000 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 500 gal | IAPMO |
InterFlo1 model
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| AO-MF-ADV1Replacement: AO-MF-ADV-R | Not stated | NSF/ANSI 53 | PFOA, PFOS | 784 gal | IAPMO |
Jabrissi6 models
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| LX001-L-Fpro-SReplacement: LX001-L-Fpro | Not stated | NSF/ANSI 53 | PFOA, PFOS | 300 gal | IAPMO |
| LX001-L-UF-Fpro-SReplacement: LX001-L-UF-Fpro | Not stated | NSF/ANSI 53 | PFOA, PFOS | 300 gal | IAPMO |
| LX001-M-Fpro-SReplacement: LX001-M-Fpro | Not stated | NSF/ANSI 53 | PFOA, PFOS | 200 gal | IAPMO |
| LX001-M-UF-Fpro-SReplacement: LX001-M-UF-Fpro | Not stated | NSF/ANSI 53 | PFOA, PFOS | 200 gal | IAPMO |
| LX001-S-Fpro-SReplacement: LX001-S-Fpro | Not stated | NSF/ANSI 53 | PFOA, PFOS | 100 gal | IAPMO |
| LX001-S-UF-Fpro-SReplacement: LX001-S-UF-Fpro | Not stated | NSF/ANSI 53 | PFOA, PFOS | 100 gal | IAPMO |
Kemflo1 model
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| KF-DWS-GReplacement: KF-DWS-G-R | Not stated | NSF/ANSI 53 | PFOA, PFOS | 1,500 gal | IAPMO |
Kinetico2 models
Kohler2 models
Kraus3 models
Kul Refreshment2 models
LARQ2 models
Leaf Home Water Solutions1 model
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| LWROReplacement: 41407003 | Reverse osmosis | NSF/ANSI 58 | PFOA, PFOS | IAPMO |
LifeWave X2O Water Technology1 model
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| LWWM-GEN1Replacement: LW-X2O-PFLT1, LW-X2O-SFLT2 | Pitcher | NSF/ANSI 53 | Total PFAS | 150 gal | IAPMO |
Mavea1 model
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| Purity C 1000 ACReplacement: 10006719 | Not stated | NSF/ANSI 53 | Total PFAS | 2,642 gal | NSF |
MaxClear4 models
Microfilter8 models
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| FP-10Replacement: FP-10R | Not stated | NSF/ANSI 53 | Total PFAS | 300 gal | NSF |
| FP-10SReplacement: FP-10SR | Not stated | NSF/ANSI 53 | Total PFAS | 300 gal | NSF |
| FP-15Replacement: FP-15R | Not stated | NSF/ANSI 53 | Total PFAS | 530 gal | NSF |
| FP-15SReplacement: FP-15SR | Not stated | NSF/ANSI 53 | Total PFAS | 530 gal | NSF |
| FP-17Replacement: FP-17R | Not stated | NSF/ANSI 53 | Total PFAS | 650 gal | NSF |
| FP-17SReplacement: FP-17SR | Not stated | NSF/ANSI 53 | Total PFAS | 650 gal | NSF |
| FP-21Replacement: FP-21R | Not stated | NSF/ANSI 53 | Total PFAS | 830 gal | NSF |
| FP-21SReplacement: FP-21SR | Not stated | NSF/ANSI 53 | Total PFAS | 830 gal | NSF |
Moen3 models
Murdock4 models
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| 7004-302-001Replacement: 7012-347-000 | Not stated | NSF/ANSI 53 | Total PFAS | 3,000 gal | IAPMO |
| 7012-347-001Replacement: 7012-347-000 | Not stated | NSF/ANSI 53 | Total PFAS | 3,000 gal | IAPMO |
| WF3000Replacement: 7012-347-000 | Not stated | NSF/ANSI 53 | Total PFAS | 3,000 gal | IAPMO |
| WF3EZReplacement: 7012-347-000 | Not stated | NSF/ANSI 53 | Total PFAS | 3,000 gal | IAPMO |
Nano Nature1 model
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| TPW2-C1 1Replacement: 1104673 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 1,325 gal | WQA |
Natural Purity/Classic Water1 model
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| QCRO5V-50Replacement: 41407614 | Reverse osmosis | NSF/ANSI 58 | PFOA, PFOS | IAPMO |
NECOA5 models
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| CHP-1300LReplacement: Z-RO 8 | Reverse osmosis | NSF/ANSI 58 | PFOA, PFOS | WQA | |
| CHP-1300LReplacement: Z-RO 8 | Reverse osmosis | NSF/ANSI 58 | PFOA, PFOS | IAPMO | |
| CHP-1301LReplacement: Z-RO 8 | Reverse osmosis | NSF/ANSI 58 | PFOA, PFOS | IAPMO | |
| CHPI-1500LReplacement: Z-RO 8 | Reverse osmosis | NSF/ANSI 58 | PFOA, PFOS | WQA | |
| CHPI-1500LReplacement: Z-RO 8 | Reverse osmosis | NSF/ANSI 58 | PFOA, PFOS | IAPMO |
NEX3 models
Ninja1 model
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| WF100X1Replacement: XSKWATFILXXX2 | Not stated | NSF/ANSI 53 | Total PFAS | 120 gal | IAPMO |
North Star1 model
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| NSROPSReplacement: 7287514, NSROPF | Reverse osmosis | NSF/ANSI 58 | PFOA, PFOS | IAPMO |
Oasis2 models
OmniFilter2 models
Omnipure5 models
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| ELF 0.5ML Premium PFOS SMS WRAPReplacement: ELF 0.5ML Premium PFOS SMS WRAP | Not stated | NSF/ANSI 53 | PFOA, PFOS | 2,500 gal | IAPMO |
| ELF 1MPFReplacement: N/A | Not stated | NSF/ANSI 53 | PFOA, PFOS | 500 gal | NSF |
| ELF XL 0.5ML Premium PFOS SMS WRAPReplacement: ELF XL 0.5ML Premium PFOS SMS WRAP | Not stated | NSF/ANSI 53 | PFOA, PFOS | 3,856 gal | IAPMO |
| ELF-XLHPAMReplacement: ELF-XLHPAM | Not stated | NSF/ANSI 53 | PFOA, PFOS | 500 gal | IAPMO |
| Q5515 PFReplacement: N/A | Not stated | NSF/ANSI 53 | PFOA, PFOS | 250 gal | NSF |
One Green Filter1 model
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| OGF-TLS-CBPFSR2Replacement: OGF-RF-CBPFSR2 | Not stated | NSF/ANSI 53 | Total PFAS | 1,925 gal | IAPMO |
Patriot Pure2 models
Pentair6 models
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| Chlorplus-Protect 10 1Replacement: Chlorplus Protect 10 Cartridge | Under-sink | NSF/ANSI 53 | Total PFAS | 1,000 gal | IAPMO |
| Easy FlowReplacement: RC-LCT | Under-sink | NSF/ANSI 53 | PFOA, PFOS | 3,000 gal | IAPMO |
| F2000-B2B 1Replacement: F2B2-RC2 | Under-sink | NSF/ANSI 53 | Total PFAS | 675 gal | IAPMO |
| F3000-B2B 1Replacement: F2B2-RC2 | Under-sink | NSF/ANSI 53 | Total PFAS | 675 gal | IAPMO |
| Floplus Protect 20BBReplacement: Floplus Protect 20BB Cartridge | Whole house | NSF/ANSI 53 | PFOA, PFOS, PFNA, PFHpA, PFHxS | 40,000 gal | IAPMO |
| GRO-575B 1Replacement: F2B2-RC2 | Under-sink | NSF/ANSI 53 | Total PFAS | 675 gal | IAPMO |
Philips3 models
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| AUT9332XX/YY 1, 2, 3Replacement: AUT833/YY 2 | Not stated | NSF/ANSI 53 | Total PFAS | 1,925 gal | IAPMO |
| AUT9333XX/YY 1, 2, 3Replacement: AUT833/YY 2 | Not stated | NSF/ANSI 53 | Total PFAS | 1,925 gal | IAPMO |
| AUT9334XX/YY 1, 2, 3Replacement: AUT833/YY 2 | Not stated | NSF/ANSI 53 | Total PFAS | 1,925 gal | IAPMO |
Pioneer3 models
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| CTA0838BBxxP5-0yyzzz1Replacement: CT-05-CB-AMCYL-38 | Whole house | NSF/ANSI 53 | PFOA, PFOS | 93,250 gal | IAPMO |
| CTA0840BBxxP5-0yyzzz1Replacement: CT-05-CB-AMCYL | Whole house | NSF/ANSI 53 | PFOA, PFOS | 100,000 gal | IAPMO |
| CTA0842BBxxP5-0yyzzz1Replacement: CT-05-CB-AMCYL-42 | Whole house | NSF/ANSI 53 | PFOA, PFOS | 106,750 gal | IAPMO |
Pioneer Drop1 model
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| FC-40PReplacement: CT-05-CB-AMYCL | Whole house | NSF/ANSI 53 | PFOA, PFOS | 100,000 gal | IAPMO |
Project Source2 models
ProOne2 models
PUR53 models
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| CR-1100CReplacement: PPF951K | Pitcher | NSF/ANSI 53 | Total PFAS | 40 gal | IAPMO |
| DS-1800ZReplacement: PPF951K | Pitcher | NSF/ANSI 53 | Total PFAS | 40 gal | IAPMO |
| DS-1800ZAMAReplacement: PPF951K | Pitcher | NSF/ANSI 53 | Total PFAS | 40 gal | IAPMO |
| DS1811BReplacement: PPF951K | Pitcher | NSF/ANSI 53 | Total PFAS | 40 gal | IAPMO |
| DS1811ZReplacement: PPF951K | Pitcher | NSF/ANSI 53 | Total PFAS | 40 gal | IAPMO |
| DS1811ZAMAReplacement: PPF951K | Pitcher | NSF/ANSI 53 | Total PFAS | 40 gal | IAPMO |
| FM-2000BReplacement: RF-3375 RF-9999 | Faucet mount | NSF/ANSI 53 | Total PFAS | 100 gal | IAPMO |
| FM-3333BReplacement: RF-3375 RF-9999 | Faucet mount | NSF/ANSI 53 | Total PFAS | 100 gal | IAPMO |
| FM-3700BReplacement: RF-3375 RF-9999 | Faucet mount | NSF/ANSI 53 | Total PFAS | 100 gal | IAPMO |
| FM2100BReplacement: RF-3375 RF-9999 | Faucet mount | NSF/ANSI 53 | Total PFAS | 100 gal | IAPMO |
| FM2500VReplacement: RF-3375 RF-9999 | Faucet mount | NSF/ANSI 53 | Total PFAS | 100 gal | IAPMO |
| FM2700GReplacement: RF-3375 RF-9999 | Faucet mount | NSF/ANSI 53 | Total PFAS | 100 gal | IAPMO |
| FM2800NReplacement: RF-3375 RF-9999 | Faucet mount | NSF/ANSI 53 | Total PFAS | 100 gal | IAPMO |
| FM4000BReplacement: RF-3375 RF-9999 | Faucet mount | NSF/ANSI 53 | Total PFAS | 100 gal | IAPMO |
| PDI4000ZReplacement: PPF951K | Pitcher | NSF/ANSI 53 | Total PFAS | 40 gal | IAPMO |
| PDI4000ZAMAReplacement: PPF951K | Pitcher | NSF/ANSI 53 | Total PFAS | 40 gal | IAPMO |
| PDS1820WReplacement: PPF951K | Pitcher | NSF/ANSI 53 | Total PFAS | 40 gal | IAPMO |
| PFM100BReplacement: RF-3375 RF-9999 | Faucet mount | NSF/ANSI 53 | Total PFAS | 100 gal | IAPMO |
| PFM150WReplacement: RF-3375 RF-9999 | Faucet mount | NSF/ANSI 53 | Total PFAS | 100 gal | IAPMO |
| PFM200BReplacement: RF-3375 RF-9999 | Faucet mount | NSF/ANSI 53 | Total PFAS | 100 gal | IAPMO |
| PFM222BReplacement: RF-3375 RF-9999 | Faucet mount | NSF/ANSI 53 | Total PFAS | 100 gal | IAPMO |
| PFM244WReplacement: RF-3375 RF-9999 | Faucet mount | NSF/ANSI 53 | Total PFAS | 100 gal | IAPMO |
| PFM270GReplacement: RF-3375 RF-9999 | Faucet mount | NSF/ANSI 53 | Total PFAS | 100 gal | IAPMO |
| PFM300VReplacement: RF-3375 RF-9999 | Faucet mount | NSF/ANSI 53 | Total PFAS | 100 gal | IAPMO |
| PFM310MReplacement: RF-3375 RF-9999 | Faucet mount | NSF/ANSI 53 | Total PFAS | 100 gal | IAPMO |
| PFM350VReplacement: RF-3375 RF-9999 | Faucet mount | NSF/ANSI 53 | Total PFAS | 100 gal | IAPMO |
| PFM360FReplacement: RF-3375 RF-9999 | Faucet mount | NSF/ANSI 53 | Total PFAS | 100 gal | IAPMO |
| PFM400HReplacement: RF-3375 RF-9999 | Faucet mount | NSF/ANSI 53 | Total PFAS | 100 gal | IAPMO |
| PFM400HCReplacement: RF-3375 RF-9999 | Faucet mount | NSF/ANSI 53 | Total PFAS | 100 gal | IAPMO |
| PFM410FReplacement: RF-3375 RF-9999 | Faucet mount | NSF/ANSI 53 | Total PFAS | 100 gal | IAPMO |
| PFM420WReplacement: RF-3375 RF-9999 | Faucet mount | NSF/ANSI 53 | Total PFAS | 100 gal | IAPMO |
| PFM450SReplacement: RF-3375 RF-9999 | Faucet mount | NSF/ANSI 53 | Total PFAS | 100 gal | IAPMO |
| PFM800HXReplacement: RF-3375 RF-9999 | Faucet mount | NSF/ANSI 53 | Total PFAS | 100 gal | IAPMO |
| PPF951K1 | Pitcher | NSF/ANSI 53 | Total PFAS | 40 gal | IAPMO |
| PPF951KX1, 2 | Pitcher | NSF/ANSI 53 | Total PFAS | 40 gal | IAPMO |
| PPT001L1Replacement: PPF951K PPF951KX | Pitcher | NSF/ANSI 53 | Total PFAS | 40 gal | IAPMO |
| PPT001N1Replacement: PPF951K PPF951KX | Pitcher | NSF/ANSI 53 | Total PFAS | 40 gal | IAPMO |
| PPT001W1Replacement: PPF951K PPF951KX | Pitcher | NSF/ANSI 53 | Total PFAS | 40 gal | IAPMO |
| PPT111B1Replacement: PPF951K PPF951KX | Pitcher | NSF/ANSI 53 | Total PFAS | 40 gal | IAPMO |
| PPT111M1Replacement: PPF951K PPF951KX | Pitcher | NSF/ANSI 53 | Total PFAS | 40 gal | IAPMO |
| PPT111W1Replacement: PPF951K PPF951KX | Pitcher | NSF/ANSI 53 | Total PFAS | 40 gal | IAPMO |
| PPT120W1Replacement: PPF951K PPF951KX | Pitcher | NSF/ANSI 53 | Total PFAS | 40 gal | IAPMO |
| PPT600F1Replacement: PPF951K | Pitcher | NSF/ANSI 53 | Total PFAS | 40 gal | IAPMO |
| PPT600Q1Replacement: PPF951K | Pitcher | NSF/ANSI 53 | Total PFAS | 40 gal | IAPMO |
| PPT600W1Replacement: PPF951K | Pitcher | NSF/ANSI 53 | Total PFAS | 40 gal | IAPMO |
| PPT650U1Replacement: PPF951K | Pitcher | NSF/ANSI 53 | Total PFAS | 40 gal | IAPMO |
| PPT650W1Replacement: PPF951K | Pitcher | NSF/ANSI 53 | Total PFAS | 40 gal | IAPMO |
| PPT650Y1Replacement: PPF951K | Pitcher | NSF/ANSI 53 | Total PFAS | 40 gal | IAPMO |
| PPT700L1Replacement: PPF951K PPF951KX | Pitcher | NSF/ANSI 53 | Total PFAS | 40 gal | IAPMO |
| PPT700P1Replacement: PPF951K PPF951KX | Pitcher | NSF/ANSI 53 | Total PFAS | 40 gal | IAPMO |
| PPT700W1Replacement: PPF951K PPF951KX | Pitcher | NSF/ANSI 53 | Total PFAS | 40 gal | IAPMO |
| PPT711B1Replacement: PPF951K PPF951KX | Pitcher | NSF/ANSI 53 | Total PFAS | 40 gal | IAPMO |
| PPT711W1Replacement: PPF951K PPF951KX | Pitcher | NSF/ANSI 53 | Total PFAS | 40 gal | IAPMO |
Pure Water Technology4 models
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| 3iRReplacement: EN1100-0004 | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO | |
| PW50RReplacement: EN1100-0004 | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO | |
| PW70RReplacement: EN1100-0004 | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO | |
| PW90RReplacement: EN1100-0004 | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO |
PureBlueH2O34 models
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| FSH-EKCB1PF3Also sold as Rocean, ZENITH, ZIPReplacement: EKCB1PF3 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 2,250 gal | IAPMO |
| FT-L4-SYS1Also sold as Rocean, ZENITH, ZIPReplacement: FT-L4-SYS-R | Not stated | NSF/ANSI 53 | PFOA, PFOS | 500 gal | IAPMO |
| GBM2-STCB51PFW2Also sold as Rocean, ZENITH, ZIPReplacement: STCB1PFW2 | Not stated | NSF/ANSI 53 | Total PFAS | 3,000 gal | IAPMO |
| GRP-CSAlso sold as Rocean, ZENITH, ZIPReplacement: GRP | Refrigerator filter | NSF/ANSI 53 | PFOA, PFOS | 170 gal | IAPMO |
| GXE-CSAlso sold as Rocean, ZENITH, ZIPReplacement: GXE | Refrigerator filter | NSF/ANSI 53 | PFOA, PFOS | 170 gal | IAPMO |
| HFM1-MCB1PFWK2Also sold as Rocean, ZENITH, ZIPReplacement: MCB1PFWK2 | Not stated | NSF/ANSI 53 | Total PFAS | 2,400 gal | IAPMO |
| HFM1-MCB1PFWK4Also sold as Rocean, ZENITH, ZIPReplacement: MCB1PFWK4 | Not stated | NSF/ANSI 53 | Total PFAS | 3,500 gal | IAPMO |
| HFM1-MCB1PFWK6Also sold as Rocean, ZENITH, ZIPReplacement: MCB1PFWK6 | Not stated | NSF/ANSI 53 | Total PFAS | 4,300 gal | IAPMO |
| HFM1-MCB1PFWKSR2Also sold as Rocean, ZENITH, ZIPReplacement: MCB1PFWKSR2 | Not stated | NSF/ANSI 53 | Total PFAS | 2,400 gal | IAPMO |
| HFM1-MCB1PFWKSR4Also sold as Rocean, ZENITH, ZIPReplacement: MCB1PFWKSR4 | Not stated | NSF/ANSI 53 | Total PFAS | 3,500 gal | IAPMO |
| HFM1-MCB1PFWKSR6Also sold as Rocean, ZENITH, ZIPReplacement: MCB1PFWKSR6 | Not stated | NSF/ANSI 53 | Total PFAS | 4,300 gal | IAPMO |
| PB-DC2-CReplacement: PB-RDC2-C | Not stated | NSF/ANSI 53 | PFOA, PFOS | 389 gal | IAPMO |
| PS-ZIP-93701Also sold as Rocean, ZENITH, ZIPReplacement: 93701 | Not stated | NSF/ANSI 53 | Total PFAS | 1,100 gal | IAPMO |
| PS-ZIP-93702Also sold as Rocean, ZENITH, ZIPReplacement: 93702 | Not stated | NSF/ANSI 53 | Total PFAS | 1,453 gal | IAPMO |
| RO4-80T-CPAlso sold as Rocean, ZENITH, ZIPReplacement: RO4-50T-SED-R RO4-50T-CB-R RO4-80T-CP-R | Not stated | NSF/ANSI 53 | PFOA, PFOS | 230 gal | IAPMO |
| STH1-CB1PF2Also sold as Rocean, ZENITH, ZIPReplacement: CB1PF2 | Not stated | NSF/ANSI 53 | Total PFAS | 1,900 gal | IAPMO |
| STH1-CB1PF4Also sold as Rocean, ZENITH, ZIPReplacement: CB1PF4 | Not stated | NSF/ANSI 53 | Total PFAS | 3,200 gal | IAPMO |
| STH1-CB1PF5W6Also sold as Rocean, ZENITH, ZIPReplacement: CB1PF5W6 | Not stated | NSF/ANSI 53 | Total PFAS | 3,000 gal | IAPMO |
| STH1-MCB1PFWK2Also sold as Rocean, ZENITH, ZIPReplacement: MCB1PFWK2 | Not stated | NSF/ANSI 53 | Total PFAS | 2,400 gal | IAPMO |
| STH1-MCB1PFWK4Also sold as Rocean, ZENITH, ZIPReplacement: MCB1PFWK4 | Not stated | NSF/ANSI 53 | Total PFAS | 3,500 gal | IAPMO |
| STH1-MCB1PFWK6Also sold as Rocean, ZENITH, ZIPReplacement: MCB1PFWK6 | Not stated | NSF/ANSI 53 | Total PFAS | 4,300 gal | IAPMO |
| STH1-MCB1PFWKSR2Also sold as Rocean, ZENITH, ZIPReplacement: MCB1PFWKSR2 | Not stated | NSF/ANSI 53 | Total PFAS | 2,400 gal | IAPMO |
| STH1-MCB1PFWKSR4Also sold as Rocean, ZENITH, ZIPReplacement: MCB1PFWKSR4 | Not stated | NSF/ANSI 53 | Total PFAS | 3,500 gal | IAPMO |
| STH1-MCB1PFWKSR6Also sold as Rocean, ZENITH, ZIPReplacement: MCB1PFWKSR6 | Not stated | NSF/ANSI 53 | Total PFAS | 4,300 gal | IAPMO |
| TLH-TLCB1CLMPH4Also sold as Rocean, ZENITH, ZIPReplacement: TLCB1CLMPH4 | Not stated | NSF/ANSI 53 | Total PFAS | 750 gal | IAPMO |
| TLH-TLCB1CP4Also sold as Rocean, ZENITH, ZIPReplacement: TLCB1CP4 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 651 gal | IAPMO |
| TLH-TLCB1PF2Also sold as Rocean, ZENITH, ZIPReplacement: TLCB1PF2 | Not stated | NSF/ANSI 53 | Total PFAS | 1,100 gal | IAPMO |
| TLH-TLCB1PFSR2Also sold as Rocean, ZENITH, ZIPReplacement: TLCB1PFSR2 | Not stated | NSF/ANSI 53 | Total PFAS | 1,925 gal | IAPMO |
| TLSH238-HFMAlso sold as Rocean, ZENITH, ZIPReplacement: TLSHF-CB-R TLSH-HFM-R | Not stated | NSF/ANSI 53 | PFOA, PFOS | 389 gal | IAPMO |
| TLSHF138Also sold as Rocean, ZENITH, ZIPReplacement: CP-2 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 389 gal | IAPMO |
| TLSHF238Also sold as Rocean, ZENITH, ZIPReplacement: CP-2 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 778 gal | IAPMO |
| UCSTH2-CP1Also sold as Rocean, ZENITH, ZIPReplacement: CP-2 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 389 gal | IAPMO |
| UCSTH4-CP1Also sold as Rocean, ZENITH, ZIPReplacement: CP-4 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 651 gal | IAPMO |
| UCSTH6-CP1Also sold as Rocean, ZENITH, ZIPReplacement: CP-6 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 784 gal | IAPMO |
Pureza6 models
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| S001-L-Fpro-SReplacement: S001-1、S001-2PRO | Not stated | NSF/ANSI 53 | PFOA, PFOS | 300 gal | IAPMO |
| S001-L-UF-Fpro-SReplacement: S001-1-UF、S001-2PRO | Not stated | NSF/ANSI 53 | PFOA, PFOS | 300 gal | IAPMO |
| S001-M-Fpro-SReplacement: S001-1、S001-2PRO | Not stated | NSF/ANSI 53 | PFOA, PFOS | 200 gal | IAPMO |
| S001-M-UF-Fpro-SReplacement: S001-1-UF、S001-2PRO | Not stated | NSF/ANSI 53 | PFOA, PFOS | 200 gal | IAPMO |
| S001-S-Fpro-SReplacement: S001-1、S001-2PRO | Not stated | NSF/ANSI 53 | PFOA, PFOS | 100 gal | IAPMO |
| S001-S-UF-Fpro-SReplacement: S001-1-UF、S001-2PRO | Not stated | NSF/ANSI 53 | PFOA, PFOS | 100 gal | IAPMO |
Purios1 model
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| WP3000(US)Replacement: WP3000(US)-RF | Not stated | NSF/ANSI 53 | Total PFAS | 3,000 gal | IAPMO |
PuROMax3 models
Puronics1 model
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| Micromax 8500Replacement: W-PN-8004 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 175 gal | WQA |
Purunity1 model
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| AQUALIS+Replacement: RO + | Reverse osmosis | NSF/ANSI 58 | PFOA, PFOS | WQA |
Quench11 models
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| Q3FSReplacement: P02284, P02256, P02284 | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO | |
| Q4FSReplacement: P02284, P02256, P02284 | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO | |
| Q5CTReplacement: P02284, P02256, P02284 | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO | |
| Q5CTEReplacement: P02284, P02256, P02284 | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO | |
| Q5FSReplacement: P02284, P02256, P02284 | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO | |
| Q7CTReplacement: P02284, P02256, P02284 | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO | |
| Q7CTEReplacement: P02284, P02256, P02284 | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO | |
| Q7FSReplacement: P02284, P02256, P02284 | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO | |
| Q8CTReplacement: P02284, P02256, P02284 | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO | |
| Q8CTEReplacement: P02284, P02256, P02284 | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO | |
| Q8FSReplacement: P02284, P02256, P02284 | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO |
Rainsoft2 models
ResinTech4 models
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| HYS-100-3612 1Replacement: AF-10-3612 | Under-sink | NSF/ANSI 53 | Total PFAS | 1,750 gal | IAPMO |
| HYS-100-B-3612 1Replacement: AF-10-3612-BB | Under-sink | NSF/ANSI 53 | Total PFAS | 3,562 gal | IAPMO |
| HYS-200-3612 1Replacement: AF-20-3612 | Under-sink | NSF/ANSI 53 | Total PFAS | 3,500 gal | IAPMO |
| HYS-200-B-3612 1Replacement: AF-20-3612-BB | Under-sink | NSF/ANSI 53 | Total PFAS | 7,125 gal | IAPMO |
Rusco1 model
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| POE1-MSReplacement: POE1-PLUS | Whole house | NSF/ANSI 53 | PFOA, PFOS | 100,000 gal | IAPMO |
Samsung4 models
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| RWP50020BWWReplacement: HAF-HIM-****-1, HAF-HIM-****-2 | Refrigerator filter | NSF/ANSI 53 | PFOA, PFOS | 330 gal | NSF |
| RWP70*15*****Replacement: HAF-HIM-****-1, HAF-HIM-****-2 | Under-sink | NSF/ANSI 53 | PFOA, PFOS | 330 gal | NSF |
| RWP90 a bc d e f ghReplacement: HAF-HIM-****-1, HAF-HIM-****-2 | Under-sink | NSF/ANSI 53 | PFOA, PFOS | 330 gal | NSF |
| RWPa4 x 2bcde yReplacement: HAF-HIM-****-1, HAF-HIM-****-2 | Under-sink | NSF/ANSI 53 | PFOA, PFOS | 330 gal | NSF |
Sloan1 model
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| 63820031Replacement: FC3000R | Not stated | NSF/ANSI 53 | Total PFAS | 3,000 gal | IAPMO |
Toppen Health5 models
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| 50101-01Replacement: RA5775508, PAC2.5-10AG50E, 32-250-10 | Whole house | NSF/ANSI 53 | Total PFAS | 6,000 gal | IAPMO |
| 50202-01Replacement: RA5775526, PAC2.5-20AG50E, 32-250-20 | Whole house | NSF/ANSI 53 | Total PFAS | 12,000 gal | IAPMO |
| 50403-02Replacement: RA5777608, PAC4.5-20AG, 32-450-20 | Whole house | NSF/ANSI 53 | Total PFAS | 25,000 gal | IAPMO |
| 50601-01Replacement: 50401-01 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 150 gal | IAPMO |
| ULTRAWBReplacement: 51001-01 | Bottle | NSF/ANSI 53 | Total PFAS | 25 gal | IAPMO |
Tupperware3 models
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| Nano Nature TPW-C1 Model Household Water Purification SystemReplacement: 59085 | Countertop | NSF/ANSI 53 | PFOA, PFOS | 1,325 gal | NSF |
| Nano Nature TPW-C2 Model Household Water Purification SystemReplacement: 59085 | Countertop | NSF/ANSI 53 | PFOA, PFOS | 1,325 gal | NSF |
| Nano Nature Water Filtration SystemReplacement: 59085 | Countertop | NSF/ANSI 53 | PFOA, PFOS | 1,325 gal | NSF |
Viking Range1 model
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| ProChill NGPTReplacement: RWFVRF1 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 125 gal | IAPMO |
Water Tech1 model
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| MC-1Replacement: MC-1FX | Under-sink | NSF/ANSI 53 | PFOA, PFOS | 500 gal | IAPMO |
Waterbird2 models
Waterdrop4 models
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| ECF-7018BB-23Replacement: ECF-7023B | Pitcher | NSF/ANSI 53 | PFOA, PFOS | 20 gal | IAPMO |
| WD-G3-WReplacement: WD-G3-CB | Under-sink | NSF/ANSI 53 | PFOA, PFOS | 1,100 gal | IAPMO |
| WD-G3P600Replacement: WD-G3-CB | Under-sink | NSF/ANSI 53 | PFOA, PFOS | 1,100 gal | IAPMO |
| WD-G3P800Replacement: WD-G3-CB | Under-sink | NSF/ANSI 53 | PFOA, PFOS | 1,100 gal | IAPMO |
Waterlogic3 models
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| WL30-ROReplacement: RO Membrane: WLRO-12 Filter and RO Membrane: WLPC-12 and WLRO-12 | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO | |
| WL50-ROReplacement: RO Membrane: WLRO-12 Filter and RO Membrane: WLPC-12 and WLRO-12 | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO | |
| WL50CT-ROReplacement: RO Membrane: WLRO-12 Filter and RO Membrane: WLPC-12 and WLRO-12 | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO |
Watts3 models
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| BB-S101Replacement: BB-C100 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 84,480 gal | IAPMO |
| H2O-DWCBTP100Also sold as A WATTS REGULATOR COMPANYReplacement: H2O-F47 | Not stated | NSF/ANSI 53 | Total PFAS | 1,900 gal | IAPMO |
| PWDWTPFAS1Also sold as A WATTS REGULATOR COMPANYReplacement: PWCBTPFAS1 | Not stated | NSF/ANSI 53 | Total PFAS | 3,200 gal | IAPMO |
Wellsys4 models
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| W5-ROReplacement: WRO-12, WPC-12, WRO-12 | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO | |
| W7-ROReplacement: WRO-12, WPC-12, WRO-12 | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO | |
| W9-ROReplacement: WRO-12, WPC-12, WRO-12 | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO | |
| W9CT-ROReplacement: WRO-12, WPC-12, WRO-12 | Reverse osmosis | NSF/ANSI 58 | Total PFAS | IAPMO |
Whirlpool6 models
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| EDR3RXD1BReplacement: EDR3RXD1B | Refrigerator filter | NSF/ANSI 53 | PFOA, PFOS | 200 gal | NSF |
| EDR3RXD1RReplacement: EDR3RXD1R | Refrigerator filter | NSF/ANSI 53 | PFOA, PFOS | 200 gal | NSF |
| P1WB2Replacement: W10790816 | Refrigerator filter | NSF/ANSI 53 | PFOA, PFOS | 200 gal | NSF |
| P1WB2LReplacement: EDR3RXD1 | Refrigerator filter | NSF/ANSI 53 | PFOA, PFOS | 200 gal | NSF |
| WHAFFSReplacement: WHAFFF | Not stated | NSF/ANSI 53 | PFOA, PFOS | 660 gal | IAPMO |
| WHAROS5Replacement: WHEERM, WHEERF | Reverse osmosis | NSF/ANSI 58 | PFOA, PFOS | IAPMO |
ZeroWater17 models
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| ZBD-040 2.5 Gal Glass DispenserReplacement: ZF-201, ZR-001, ZR-006, ZR-008, ZR-012, ZR-016, ZR-017 | Pitcher | NSF/ANSI 53 | PFOA, PFOS | 15 gal | IAPMO |
| ZD-010RPReplacement: ZF-201, ZR-001, ZR-006, ZR-008, ZR-012, ZR-016, ZR-017 | Pitcher | NSF/ANSI 53 | PFOA, PFOS | 15 gal | IAPMO |
| ZD-012RPReplacement: ZF-201, ZR-001, ZR-006, ZR-008, ZR-012, ZR-016, ZR-017 | Pitcher | NSF/ANSI 53 | PFOA, PFOS | 15 gal | IAPMO |
| ZD-018Replacement: ZF-201, ZR-001, ZR-006, ZR-008, ZR-012, ZR-016, ZR-017 | Pitcher | NSF/ANSI 53 | PFOA, PFOS | 15 gal | IAPMO |
| ZD-022-RRReplacement: ZF-201, ZR-001, ZR-006, ZR-008, ZR-012, ZR-016, ZR-017 | Pitcher | NSF/ANSI 53 | PFOA, PFOS | 15 gal | IAPMO |
| ZD-023-1Replacement: ZF-201, ZR-001, ZR-006, ZR-008, ZR-012, ZR-016, ZR-017 | Pitcher | NSF/ANSI 53 | PFOA, PFOS | 15 gal | IAPMO |
| ZD-030RP 30 Cup Ready-Pour DispenserReplacement: ZF-201, ZR-001, ZR-006, ZR-008, ZR-012, ZR-016, ZR-017 | Pitcher | NSF/ANSI 53 | PFOA, PFOS | 15 gal | IAPMO |
| ZD-032-RRReplacement: ZF-201, ZR-001, ZR-006, ZR-008, ZR-012, ZR-016, ZR-017 | Pitcher | NSF/ANSI 53 | PFOA, PFOS | 15 gal | IAPMO |
| ZD-052-RRReplacement: ZF-201, ZR-001, ZR-006, ZR-008, ZR-012, ZR-016, ZR-017 | Pitcher | NSF/ANSI 53 | PFOA, PFOS | 15 gal | IAPMO |
| ZD-20RPN 20-CupReplacement: ZF-201, ZR-001, ZR-006, ZR-008, ZR-012, ZR-016, ZR-017 | Pitcher | NSF/ANSI 53 | PFOA, PFOS | 15 gal | IAPMO |
| ZFM-400CRReplacement: ZRFM-001 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 400 gal | WQA |
| ZFM-400WHReplacement: ZRFM-001 | Not stated | NSF/ANSI 53 | PFOA, PFOS | 400 gal | WQA |
| ZP-007RPReplacement: ZF-201, ZR-001, ZR-006, ZR-008, ZR-012, ZR-016, ZR-017 | Pitcher | NSF/ANSI 53 | PFOA, PFOS | 15 gal | IAPMO |
| ZP-010Replacement: ZF-201, ZR-001, ZR-006, ZR-008, ZR-012, ZR-016, ZR-017 | Pitcher | NSF/ANSI 53 | PFOA, PFOS | 15 gal | IAPMO |
| ZP-012-RRReplacement: ZF-201, ZR-001, ZR-006, ZR-008, ZR-012, ZR-016, ZR-017 | Pitcher | NSF/ANSI 53 | PFOA, PFOS | 15 gal | IAPMO |
| ZR-0810GN 8-Cup Ready-Pour Round PitcherReplacement: ZF-201, ZR-001, ZR-006, ZR-008, ZR-012, ZR-016, ZR-017 | Pitcher | NSF/ANSI 53 | PFOA, PFOS | 15 gal | IAPMO |
| ZR-0810N 10-Cup Ready-Pour Round PitcherReplacement: ZF-201, ZR-001, ZR-006, ZR-008, ZR-012, ZR-016, ZR-017 | Pitcher | NSF/ANSI 53 | PFOA, PFOS | 15 gal | IAPMO |
Zip HydroTap15 models
| Model | Type | Standard | PFAS claim | Capacity | Registry |
|---|---|---|---|---|---|
| BC (1215US 230V and 5466US 120V)1Replacement: 93701, 93701NZ | Not stated | NSF/ANSI 53 | Total PFAS | 1,100 gal | IAPMO |
| BC Home (H5xx84yyyU1)7, 8, 9Replacement: 93701, 93701NZ | Not stated | NSF/ANSI 53 | Total PFAS | 1,100 gal | IAPMO |
| BC100/75 (2825US)2Replacement: 93701, 93701NZ | Not stated | NSF/ANSI 53 | Total PFAS | 1,100 gal | IAPMO |
| BC160/125 (5060US 230V)1Replacement: 93702, 93702NZ | Not stated | NSF/ANSI 53 | Total PFAS | 1,453 gal | IAPMO |
| BC40 (H5xx03yyyU2)7, 8, 9Replacement: 93702, 93702NZ | Not stated | NSF/ANSI 53 | Total PFAS | 1,453 gal | IAPMO |
| BCS (1256US 230V and 5467US 120V)3Replacement: 93701, 93701NZ | Not stated | NSF/ANSI 53 | Total PFAS | 1,100 gal | IAPMO |
| BCS Home (H5xx83yyyU1)5, 8, 9Replacement: 93701, 93701NZ | Not stated | NSF/ANSI 53 | Total PFAS | 1,100 gal | IAPMO |
| BCS100/75 (2587US)4Replacement: 93701, 93701NZ | Not stated | NSF/ANSI 53 | Total PFAS | 1,100 gal | IAPMO |
| BCS160/175 (5053US 230V)3Replacement: 93702, 93702NZ | Not stated | NSF/ANSI 53 | Total PFAS | 1,453 gal | IAPMO |
| BCS20 (H5xx60yyyU2)5, 8, 9Replacement: 93702, 93702NZ | Not stated | NSF/ANSI 53 | Total PFAS | 1,453 gal | IAPMO |
| BCS60 (H5xx62yyyU2)5, 8, 9Replacement: 93702, 93702NZ | Not stated | NSF/ANSI 53 | Total PFAS | 1,453 gal | IAPMO |
| CS Home (H5xx87yyyU1)6, 9Replacement: 93701, 93701NZ | Not stated | NSF/ANSI 53 | Total PFAS | 1,100 gal | IAPMO |
| CS100 (H5xx65yyyU2)6, 9Replacement: 93702, 93702NZ | Not stated | NSF/ANSI 53 | Total PFAS | 1,453 gal | IAPMO |
| CS175 (0053US 230V)1Replacement: 93702, 93702NZ | Not stated | NSF/ANSI 53 | Total PFAS | 1,453 gal | IAPMO |
| CS75 (0056US)1Replacement: 93701, 93701NZ | Not stated | NSF/ANSI 53 | Total PFAS | 1,100 gal | IAPMO |
Registries checked November 17, 2026. Certifications change: always confirm the listing before you buy. Brands not on this list had no PFAS claim under NSF/ANSI 53 or 58 in these registries on that date. See How we test.
Questions people ask
Which water filters are certified to remove PFAS?
As of November 17, 2026, the NSF, WQA and IAPMO R&T registries list 638 drinking water filter models from 100 brands as certified to reduce PFAS under NSF/ANSI 53 or NSF/ANSI 58. 302 of them carry the newer "Total PFAS" claim. Most well-known brands hold their PFAS certificates at IAPMO R&T or WQA, not at NSF, so checking NSF alone misses most of this list.
What does a PFOA/PFOS claim mean versus Total PFAS?
Both are certified reduction claims under NSF/ANSI 53 or 58. A PFOA/PFOS claim covers those two compounds; the newer Total PFAS claim, added by NSF in 2022, covers a wider group of PFAS. EPA’s home filter fact sheet (April 2024) notes that filter certifications do not yet show reduction down to EPA’s 4.0 ppt drinking water limits.
Is my Brita, PUR or ZeroWater filter certified for PFAS?
Some models are. Search the brand in the list on this page and match the exact model and replacement filter number. If your model is not listed with a PFAS claim, the box or website claim is not backed by a registry certification.
Why is a brand missing from this list?
Because none of its models is listed with a PFAS reduction claim under NSF/ANSI 53 or 58 in the NSF, WQA or IAPMO registries on the date shown. Lab test reports a brand publishes itself ("tested to") do not count as certification.
How do I verify a filter myself?
Open the registry link next to the model. The listing names the certified model, the replacement element, the capacity in gallons and the claims. Search NSF at info.nsf.org, WQA at find.wqa.org and IAPMO at pld.iapmo.org.